Offshore cathodic protection and marine infrastructure
// HELE TITANIUM · CATHODIC PROTECTION SOLUTIONS

Cathodic Protection Systems & MMO Anodes

Engineered for pipelines, storage tanks, offshore structures, marine assets, reinforced concrete, and buried infrastructure. Hele Titanium provides MMO anodes, ICCP anodes, CP cables, reference electrodes, and cathodic protection accessories for long-term corrosion control.

> ICCP System Support
> MMO Tubular / Ribbon / Wire Anodes
> CP Cables & Reference Electrodes
> Project-Specific Documentation

Electrochemical Asset Preservation

By applying a controlled electrical current, we shift the electrochemical potential of critical infrastructure into a non-corroding range.

Cathodic protection effectively converts a vulnerable metal structure from a naturally corroding anode into a protected cathode. This electrochemical shift permanently suppresses corrosion reactions even in the most aggressive industrial environments.

01

Controlled Current Input

Precision ICCP anodes deliver a calculated electrical current to the structure.

02

Potential Shift

The metal's electrochemical potential is forced into a highly negative, immune state.

03

Corrosion Suppression

Anodic dissolution is halted, permanently preserving structural

SYSTEM ARCHITECTURE

How Cathodic Protection Works

A cathodic protection system protects steel infrastructure by making the asset act as the cathode in an electrochemical circuit. The anode system supplies protective current, while cables, power equipment, and reference electrodes help distribute and monitor system performance.

SYSTEM CONFIGURATION

Typical ICCP System Configuration

An impressed current cathodic protection system uses a DC power source to drive protective current from MMO titanium anodes through the surrounding electrolyte to the protected steel structure. Reference electrodes, CP cables, and monitoring points help control system performance and verify protection potential over time.

Core System Elements

1
Protected Structure

The pipeline, tank, offshore structure, marine asset, or reinforced concrete component that requires corrosion protection.

2
Anode System

MMO, ICCP, tubular, ribbon, wire, or canistered anodes provide the protective current required by the system design.

3
Power / Current Source

For impressed current cathodic protection systems, a rectifier or power source controls current output based on project requirements.

4
Cables & Connections

CP cables, junction boxes, and connection hardware help transmit current reliably across the protection system.

5
Reference Electrodes & Monitoring

Reference electrodes and test points help monitor protection potential and support long-term system verification.

Technical Reference: Core Reactions

While the system architecture handles distribution, the core mechanism relies on controlled electrochemical reactions at the anode and protected asset.

Anode Reaction (Oxygen Evolution Dominant)
2H₂O → O₂ + 4H⁺ + 4e⁻
Cathodic Reaction (Protected Structure)
O₂ + 2H₂O + 4e⁻ → 4OH⁻
ICCP Technical Schematic
DC Power Supply / Rectifier
MMO Coated Titanium Anodes
CP Cable Connections
Reference Electrodes & Test Points
Protected Steel Structure
Monitoring / Junction Box

Buyer Note: Final ICCP layout depends on asset type, electrolyte environment, coating condition, current demand, cable length, design life, and monitoring requirements.

Selection Guide

How to Choose the Right Cathodic Protection Solution

Different assets require different cathodic protection designs, anode formats, installation methods, and monitoring accessories. Use the guide below to identify the right direction before requesting a CP review or quotation.

Long Buried Pipelines

Recommended CP Direction

Impressed current cathodic protection system

Typical Products
MMO tubular anodes CP cables Reference electrodes Test station accessories

Storage Tank Bottoms

Recommended CP Direction

Distributed current protection below tank floors

Typical Products
MMO ribbon anodes MMO tubular anodes Reference electrodes CP cables

Offshore Platforms

Recommended CP Direction

Marine ICCP protection for seawater-exposed structures

Typical Products
MMO titanium anodes ICCP anodes Marine CP cables Reference electrodes

Reinforced Concrete

Recommended CP Direction

Discrete, mesh, ribbon, or distributed anode system

Typical Products
MMO mesh anodes Ribbon anodes Reference electrodes CP cables

Ports, Jetties & Marine Structures

Recommended CP Direction

Seawater-exposed cathodic protection system

Typical Products
ICCP anodes MMO anodes CP cables Monitoring electrodes

Found your application?

Let our engineering team design the exact CP system you need.

Choose the Right Anode Format for Your Asset

Different CP projects require different anode geometries, installation methods, and current distribution strategies. Hele Titanium provides multiple MMO anode formats to match pipelines, tanks, concrete structures, marine assets, and custom ICCP systems.

MMO Ribbon Anodes

MMO Ribbon Anodes

Best For

Tank bottoms, reinforced concrete, and distributed current systems.

Typical Environment

Soil, concrete, tank foundation, or wide-area protection zones.

Buyer Note

Ribbon anodes help improve current distribution across large protected areas.

MMO Tubular Anodes

MMO Tubular Anodes

Best For

Deep groundbeds, pipelines, tank farms, and long-life ICCP systems.

Typical Environment

Soil, coke breeze backfill, deep well groundbeds, and impressed current systems.

Buyer Note

Tubular anodes are suitable when stable current output and long operating life are required.

MMO Rod / Wire Anodes

MMO Rod / Wire Anodes

Best For

Compact CP layouts, localized protection, and custom system designs.

Typical Environment

Small spaces, localized protection zones, internal systems, or special geometries.

Buyer Note

Rod and wire formats can be adapted to project geometry and installation constraints.

Canistered Anodes

Canistered Anodes

Best For

Packaged soil installations, distributed beds, and simplified field installation.

Typical Environment

Soil environments, pre-packaged backfill systems, and remote CP installations.

Buyer Note

Pre-packaged anode systems can simplify installation and current distribution.

Infrastructure Corrosion Risks

Cathodic protection is used where electrochemical corrosion can threaten asset integrity, service life, and maintenance cost.

Seawater Corrosion

Marine and offshore structures face chloride exposure, splash-zone attack, and continuous seawater contact.

Recommended Support

Marine ICCP anodes, MMO titanium anodes, reference electrodes, and marine CP cables.

Soil Corrosion

Buried pipelines and tanks can be affected by soil resistivity, moisture, coating defects, and stray current.

Recommended Support

MMO tubular anodes, CP cables, reference electrodes, and test station accessories.

Offshore & Port Exposure

Jetties, terminals, offshore platforms, and marine structures often face severe corrosion and difficult maintenance access.

Recommended Support

ICCP anodes, MMO anodes, marine CP cables, and monitoring electrodes.

Rising Lifecycle Cost

Insufficient corrosion protection can increase inspection cost, repair frequency, downtime, and replacement risk.

Recommended Support

Long-life MMO anodes, engineered current distribution, traceable documentation, and replacement planning.

Common CP Engineering Questions

Quick answers to help procurement teams, EPC engineers, and corrosion specialists prepare a CP anode inquiry.

What information is needed for a CP anode quotation?
Please provide asset type, environment, structure size, soil or seawater conditions, current demand, anode format, cable length, design life, drawings, and documentation requirements.
How do I choose between MMO tubular, ribbon, wire, and canistered anodes?
The choice depends on asset geometry, installation method, current distribution, environment, and design life. Tubular anodes are common for ICCP groundbeds, ribbon anodes for distributed protection, and canistered anodes for packaged soil installations.
Can Hele Titanium provide CP cables and reference electrodes together with anodes?
Yes. Hele Titanium can support MMO anodes, CP cables, reference electrodes, and related cathodic protection accessories based on project requirements.
Can MMO anodes be customized for soil, seawater, tank, or concrete applications?
Yes. MMO anode geometry, coating, cable connection, dimension, and packaging can be customized based on the operating environment and CP system design.
What documents can be provided with CP anode orders?
Available documents may include material records, coating information, inspection reports, datasheets, packing lists, and project-specific quality documents.

What We Need for a CP Design Review

To recommend the right MMO anode format, cable configuration, and CP accessory package, please share as much project information as possible.

1. Structure Type

Pipeline, storage tank, offshore platform, jetty, reinforced concrete, buried structure, or other asset.

2. Dimensions or Protected Area

Structure size, coating area, tank bottom area, pipeline length, or concrete surface area.

3. Operating Environment

Soil resistivity, seawater exposure, moisture, temperature, chemical exposure, or concrete chloride condition.

4. Coating Condition

Existing coating type, coating quality, expected coating breakdown, or bare structure condition.

5. Current Demand & Design Life

Required current output, design life target, and expected operating conditions.

6. Anode Format Preference

Tubular, ribbon, wire, rod, canistered, mesh, or not sure.

7. Cable & Monitoring Requirements

Cable length, reference electrode type, test station requirement, junction box, and monitoring points.

8. Documentation Requirements

Drawings, datasheets, inspection records, packing list, certificates, and project-specific QC documents.

Cathodic Protection Inquiry

Protect Your Infrastructure with Engineered CP Anodes

Tell us about your asset type, operating environment, current demand, anode format, cable length, monitoring requirements, design life, drawings, and documentation needs. Our engineering team will recommend the right MMO anode, ICCP component, or cathodic protection accessory package.

  • Factory-Direct Technical Support
  • CP System Engineering Support
  • MMO Anode Format Selection
  • Traceable Quality Documentation

HQ: Room 1206, Building 1, Huaxia Yue World

We typically respond within 24 hours.